Update documentation
Add instructions about wiring
This commit is contained in:
parent
d4140f02a2
commit
b145d1e6d6
1 changed files with 22 additions and 2 deletions
|
@ -1,3 +1,21 @@
|
||||||
|
# Unit board communcation
|
||||||
|
|
||||||
|
## Wiring
|
||||||
|
|
||||||
|
```
|
||||||
|
┌---------┐
|
||||||
|
|? ? ? A G|
|
||||||
|
|? ? ? B V|
|
||||||
|
└---|_|---┘
|
||||||
|
|
||||||
|
A: RS-485 A/-
|
||||||
|
B: RS-485 B/+
|
||||||
|
V: Vcc
|
||||||
|
G: GND
|
||||||
|
?: Unknown
|
||||||
|
```
|
||||||
|
|
||||||
|
This diagram shows the female IDC connector that is present on the ribbon cable with the notch positioned downwards. Connect a 12V power supply to the Vcc and GND pins. To communicate with the wedges connect a RS-485 transceiver to the A and B pins, additionally connect the ground of the transceiver to the GND pin. The unit boards communicate with a baud-rate of 921600.
|
||||||
|
|
||||||
## Command Packet Structure
|
## Command Packet Structure
|
||||||
|
|
||||||
|
@ -8,6 +26,8 @@
|
||||||
For the address the following values are used:
|
For the address the following values are used:
|
||||||
- Unit Boards -> Sync Board: 0xD0 + Unit Board ID
|
- Unit Boards -> Sync Board: 0xD0 + Unit Board ID
|
||||||
- Sync Board -> Unit Boards: 0xE0 + Unit Board ID
|
- Sync Board -> Unit Boards: 0xE0 + Unit Board ID
|
||||||
|
|
||||||
|
The address correlates to the id set on the rotary switch on the unit board.
|
||||||
#### Command ID
|
#### Command ID
|
||||||
The following Command ID's are known:
|
The following Command ID's are known:
|
||||||
- 0xA8: Get Unit Board Version
|
- 0xA8: Get Unit Board Version
|
||||||
|
@ -15,7 +35,7 @@ The following Command ID's are known:
|
||||||
- 0x94: Set Thresholds
|
- 0x94: Set Thresholds
|
||||||
- 0x90: "Initialize" unit board
|
- 0x90: "Initialize" unit board
|
||||||
- 0xA1: Poll touch state
|
- 0xA1: Poll touch state
|
||||||
- 0xA3: Poll touch state (Analogue) (Not tested yed)
|
- 0xA3: Poll touch state (Analogue) (Untested)
|
||||||
#### Variable Data
|
#### Variable Data
|
||||||
This contains data, it has a variable length.
|
This contains data, it has a variable length.
|
||||||
#### Checksum
|
#### Checksum
|
||||||
|
@ -75,7 +95,7 @@ The sync board sends:
|
||||||
The unit boards respond with:
|
The unit boards respond with:
|
||||||
|
|
||||||
`0xD1 0xA1 0x80 0x00 0x00 0x00 0x04 0x00 0x00 0x00 0x00 0x00 0x00 0x01 0x75 0xF0`
|
`0xD1 0xA1 0x80 0x00 0x00 0x00 0x04 0x00 0x00 0x00 0x00 0x00 0x00 0x01 0x75 0xF0`
|
||||||
#### 0xA3 - Poll touch state (Analogue)
|
#### 0xA3 - Poll touch state (Analogue) (Untested)
|
||||||
This command retrieves the touch state from the unit boards.
|
This command retrieves the touch state from the unit boards.
|
||||||
The sync board sends:
|
The sync board sends:
|
||||||
|
|
||||||
|
|
Loading…